{"id":407,"date":"2012-05-24T18:29:26","date_gmt":"2012-05-24T18:29:26","guid":{"rendered":"http:\/\/landviser.biz\/dotcomsandbox\/?p=407"},"modified":"2017-08-29T18:33:41","modified_gmt":"2017-08-29T18:33:41","slug":"detect-groundwater-levels","status":"publish","type":"post","link":"http:\/\/landviser.biz\/dotcomsandbox\/detect-groundwater-levels\/","title":{"rendered":"Vertical Electrical Sounding to Detect Groundwater Levels in Arid Areas"},"content":{"rendered":"<div id=\"pl-407\"  class=\"panel-layout\" ><div id=\"pg-407-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-407-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-407-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><img decoding=\"async\" src=\"http:\/\/www.landviser.net\/webfm_send\/126\" alt=\"hydrology of delta Volga, Russia\" \/><\/p>\n<p class=\"rtejustify\">Water and salt content distributions within the soil profile are the main properties causing considerable variations in electrical resistivity. In arid areas, the water content and salt distributions are determined mainly\u00a0 by the saline groundwater, rather then by precipitation.<\/p>\n<p class=\"rtejustify\">The soil profile is divided into a top unsaturated layer with high resistivity and a bottom layer saturated by saline groundwater with low resistivity. Considering large differences in electrical resistivity between the unsaturated and saturated zones, the VES method was applied to detect the saline groundwater level.<\/p>\n<p class=\"rtejustify\">The approximate location of the groundwater table was estimated by a visual inspection of the VES curve. The AB\/2 value with the sharp change to the low resistivity (3-20 ohm m) was selected from each VES profile and multiplied by an empirical coefficient (0.32 for the investigated soils). These coefficients vary from 0.28 to 0.34 for other soil types (Barker, 1989).\u00a0 For example, for VES 6 the AB\/2 with such sharp change is 7.2 m and the groundwater table is estimated as 7.2x0.32=2.3 m. In some cases (VES 3) it was difficult to visually determinate where the VES curve has a sharp change in electrical resistivity. Nevertheless, with the computer interpretation of the VES data we could determine the changes more accurately. The results of the computer interpretation of the VES data were compared with the real groundwater tables measured in bore-holes and the relative errors of the VES estimation varied from 3 to 11% as shown in Table.<\/p>\n<p class=\"rtejustify\"><img decoding=\"async\" src=\"http:\/\/www.landviser.net\/webfm_send\/167\" alt=\"VES curve to detect depth to groundwater\" \/><\/p>\n<p><strong>Reference:<\/strong>\u00a0Barker, R.D.\u00a0 1989.\u00a0 Depth of investigation of collinear symmetrical four-electrode arrays.\u00a0 Geophysics.\u00a0 54:1031-1037.<\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\" align=\"left\">\n<tbody>\n<tr>\n<td>\n<p class=\"rtecenter\">Case number<\/p>\n<\/td>\n<td colspan=\"2\">\n<p class=\"rtecenter\">Groundwater table<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">Relative estimation error<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td>\n<p class=\"rtecenter\">Real\u00a0\u00a0\u00a0\u00a0 (bore hole)<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">Estimated (VES)<\/p>\n<\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td colspan=\"2\">\n<p class=\"rtecenter\">\u2014\u2014\u2014 m \u2014\u2014\u2014\u2014<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">\u2014\u2014 % \u2014\u2014<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">1<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">2.19<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">2.37<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">7<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">2<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.15<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.29<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">11<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">3<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">2.47<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">2.55<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">3<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">4<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">2.38<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">2.25<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">5<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.60<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.53<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">5<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">6<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.17<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.34<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">7<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.32<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.22<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">8<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p class=\"rtecenter\">8<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.38<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">1.24<\/p>\n<\/td>\n<td>\n<p class=\"rtecenter\">10<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"rtecenter\">Mean<\/td>\n<td><\/td>\n<td><\/td>\n<td>\n<p class=\"rtecenter\">8<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Water and salt content distributions within the soil profile are the main properties causing considerable variations in electrical resistivity. In arid areas, the water content and salt distributions are determined mainly\u00a0 by the saline groundwater, rather then by precipitation. The soil profile is divided into a top unsaturated layer with high resistivity and a bottom layer saturated by saline groundwater with low resistivity. Considering large differences in electrical resistivity between the unsaturated and saturated zones,&hellip; <a href=\"http:\/\/landviser.biz\/dotcomsandbox\/detect-groundwater-levels\/\" class=\"more-link\">Read more <span class=\"screen-reader-text\">about Vertical Electrical Sounding to Detect Groundwater Levels in Arid Areas<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":409,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[3,20],"tags":[],"class_list":["post-407","post","type-post","status-publish","format-standard","has-post-thumbnail","category-agriculture","category-geophysics","entry"],"_links":{"self":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts\/407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/comments?post=407"}],"version-history":[{"count":4,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts\/407\/revisions"}],"predecessor-version":[{"id":1027,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts\/407\/revisions\/1027"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/media\/409"}],"wp:attachment":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/media?parent=407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/categories?post=407"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/tags?post=407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}