{"id":493,"date":"2013-02-08T21:21:20","date_gmt":"2013-02-08T21:21:20","guid":{"rendered":"http:\/\/landviser.biz\/dotcomsandbox\/?p=493"},"modified":"2017-08-28T15:06:14","modified_gmt":"2017-08-28T15:06:14","slug":"calibrate-k-coefficient","status":"publish","type":"post","link":"http:\/\/landviser.biz\/dotcomsandbox\/calibrate-k-coefficient\/","title":{"rendered":"Calibrate (calculate) K-coefficient for laboratory four-electrode cell"},"content":{"rendered":"<div id=\"pl-493\"  class=\"panel-layout\" ><div id=\"pg-493-0\"  class=\"panel-grid panel-no-style\" ><div id=\"pgc-493-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-493-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div\n\t\t\t\n\t\t\tclass=\"so-widget-sow-editor so-widget-sow-editor-base\"\n\t\t\t\n\t\t>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><img fetchpriority=\"high\" fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-medium wp-image-496\" src=\"http:\/\/landviser.biz\/dotcomsandbox\/wp-content\/uploads\/2017\/08\/slide14-300x225.jpg\" alt=\"\" width=\"300\" height=\"225\" srcset=\"http:\/\/landviser.biz\/dotcomsandbox\/wp-content\/uploads\/2017\/08\/slide14-300x225.jpg 300w, http:\/\/landviser.biz\/dotcomsandbox\/wp-content\/uploads\/2017\/08\/slide14-768x576.jpg 768w, http:\/\/landviser.biz\/dotcomsandbox\/wp-content\/uploads\/2017\/08\/slide14.jpg 960w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p class=\"rtejustify\">Laboratory cells supplied by Landviser, LLC have been calibrated and the respective K-geometric coefficient is printed on the cell. The cells have to be filled to the top rim, in order for the coefficient to be accurate. Also, sometimes due to corrosion of conductive plates (electrodes) the coefficient of the cell might change slightly. Thus, you can verify K-coefficient of any cell, just follow instructions below.<\/p>\n<p><strong>For other tips, download\u00a0<a href=\"http:\/\/www.landviser.net\/webfm_send\/102\">Measuring Properties of Natural Systems with LandMapper ERM-02 (manual)<\/a><\/strong><\/p>\n<p><strong>Materials:<\/strong><\/p>\n<table border=\"1\" cellspacing=\"1\" cellpadding=\"1\" align=\"right\">\n<tbody>\n<tr>\n<td><img decoding=\"async\" src=\"http:\/\/www.landviser.net\/sites\/default\/files\/4-el-cell.jpg\" alt=\"\" \/><\/td>\n<\/tr>\n<tr>\n<td>Fig. Scheme of the four-electrode laboratory conductivity cell. Electrical field lines are shown with thin straight lines (uniform electrical field).<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ol>\n<li>Laboratory cell with embedded four-electrodes<\/li>\n<li>Distilled water and standard resistivity solution (f.e. from Fisher Scientific, Inc.)<\/li>\n<li>LandMapper with four banana plugs to alligator clips connectors.<\/li>\n<\/ol>\n<p><strong>Procedure:<\/strong><\/p>\n<ol>\n<li class=\"rtejustify\">Connect LandMapper to electrodes embedded in the cell. Landviser\u2019s supplied rectangular cells have current (AB) electrodes as metal plates at the end of rectangular prism and potential (MN) electrodes as wire lines embedded on the front. Connect LandMapper terminals accordingly.<\/li>\n<li>Fill cell with standard solution (<strong>ERss=X<\/strong>) with known resistivity. Measure ER on K0=1.<\/li>\n<li>Record measured resistivity\u00a0<strong>ERm=Y<\/strong>.<\/li>\n<li>Measured ER times cell K-coefficient should be equal ERss:<\/li>\n<\/ol>\n<p><strong>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 ERss=K*ERm<\/strong><\/p>\n<p>Therefore, K of the cell is equal\u00a0<strong>ERss<\/strong>\u00a0divided by\u00a0<strong>ERm<\/strong>:<\/p>\n<p><strong>K= ERss\/ERm<\/strong><\/p>\n<ol>\n<li value=\"5\">Verify with distilled water (ER ~ 1000 Ohm m) or other standard resistivity solution.<\/li>\n<\/ol>\n<h3 class=\"location-locations-header\">Location<\/h3>\n<div class=\"location-locations-wrapper\">\n<div class=\"location vcard\">\n<div class=\"adr\"><span class=\"fn\">USDA-ARS<\/span>\u00a0<span class=\"locality\">Washington D.C.<\/span>,\u00a0<span class=\"region\">MD<\/span>\u00a0<span class=\"geo\"><abbr class=\"latitude\" title=\"38.895112\">38\u00b0 53' 42.4032\" N<\/abbr>,\u00a0<abbr class=\"longitude\" title=\"-77.036366\">77\u00b0 2' 10.9176\" W<\/abbr><\/span><\/div>\n<div class=\"map-link\">\n<div class=\"location map-link\">See map:\u00a0<a href=\"http:\/\/maps.google.com\/?q=38.895112+-77.036366+%28%2C+Washington+D.C.%2C+MD%2C+%2C+us%29\" target=\"_blank\" rel=\"noopener\">Google Maps<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Laboratory cells supplied by Landviser, LLC have been calibrated and the respective K-geometric coefficient is printed on the cell. The cells have to be filled to the top rim, in order for the coefficient to be accurate. Also, sometimes due to corrosion of conductive plates (electrodes) the coefficient of the cell might change slightly. Thus, you can verify K-coefficient of any cell, just follow instructions below. For other tips, download\u00a0Measuring Properties of Natural Systems with&hellip; <a href=\"http:\/\/landviser.biz\/dotcomsandbox\/calibrate-k-coefficient\/\" class=\"more-link\">Read more <span class=\"screen-reader-text\">about Calibrate (calculate) K-coefficient for laboratory four-electrode cell<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":496,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[29,40,41,20,32,24],"tags":[],"class_list":["post-493","post","type-post","status-publish","format-standard","has-post-thumbnail","category-diy","category-equipment","category-geophysical-equipment","category-geophysics","category-landmapper","category-soil-science","entry"],"_links":{"self":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts\/493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/comments?post=493"}],"version-history":[{"count":4,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts\/493\/revisions"}],"predecessor-version":[{"id":989,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/posts\/493\/revisions\/989"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/media\/496"}],"wp:attachment":[{"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/media?parent=493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/categories?post=493"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/landviser.biz\/dotcomsandbox\/wp-json\/wp\/v2\/tags?post=493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}